- 摘 要
-
米文杰
(常州市規(guī)劃設(shè)計院,常州 213003)[摘要] 本文通過實際工程中結(jié)構(gòu)模型的優(yōu)化分析,總結(jié)了剪力墻結(jié)構(gòu)豎向構(gòu)件布置原則,可為結(jié)構(gòu)設(shè)計人員作為設(shè)計參考。在結(jié)構(gòu)模型參數(shù)的分析中應做到全面細致,對于文本參數(shù)和圖形參數(shù)應結(jié)合參考。結(jié)構(gòu)參數(shù)控制的是否合理直接關(guān)系到工程最終的經(jīng)濟性能。
[關(guān)鍵詞] 剪力墻結(jié)構(gòu);模型參數(shù);結(jié)構(gòu)優(yōu)化
中圖分類號:TU276.4 文獻標識碼:A 文章編號:1002 -848X( 2011) Sl -0604-04Jinsheng homeworld parcel 3#,5# building structure optimization analysis
Mi Wenjie
( Changzhou Institute of Planning and Design, Changzhou 213003, China)Abstract: Through the actual project in structural model optimized analysis, the shearing force wall structure vertical component arrangement principle was summarized, which can be the design reference for the structural design personnel. We should achieve comprehensively in the structural model parameter's analysis careful, and should unify the reference regarding the text parameter and the graph parameter. Whether the design parameter control is reasonable will affect the project final econonucal performance directly.
Keywords: shearing force wall structure; model parameter; structure optimization