- 摘 要
-
劉 政
(北京中天元工程設計有限責任公司,北京 100142)[摘要] 在計算某框架結構地下車庫時,新抗震規(guī)范GB50010-2010已經執(zhí)行,但當時所采用的結構計算軟件PKPM暫未更新,此時,需要依據新規(guī)范對現(xiàn)行軟件進行判斷驗算,并對軟件參數(shù)做出適當調整,使其滿足新抗規(guī)要求。
[關鍵詞] 抗震規(guī)范;PKPM08;抗震等級;體積配箍率
中圖分類號:TU311.41 文獻標識碼:A 文章編號:1002-848X(2011) Sl-0680-03Structural design of the garage based on GB50010-2010 by PKPM
Liu Zheng
( Beijing Zhongtianyuan Architects &Engineers Ltd., Beijing 100142, China)Abstract: Code for seismic design of buildings( GB50010-2010) has be effective in structure design, when designing a garage. But the PKPM software can't cooperate with it then. In that case, the PKPM parameters accordingly to cooperate with GB50010-2010 should be adjusted.
Keywords: Code for seismic design of buildings; PKPM08; structural seismic class; volume with a hoop rate